• Out-of-Stock
HYREZ RT
HYREZ RT
Pack Size: 25kg

HYREZ RT

Package: 25kg

6-8 mm Polyurethane Floor Screed

HYREZ-RT has been infused with an exceptionally high amount of resin to provide outstanding chemical and stain resistance. Yet retaining slip resistance vital in wet areas. HYREZ-RT is a rake applied polyurethane floor screed for heavy duty industrial use. Highly chemical, abrasion and impact resistant, with a textured surface for added slip resistance but still allowing hygienic cleanliness and seamless flooring. Supplied in a variety of colours for use in environments that range from back of house to wash bays, warehousing to food processing areas.

Download our Spec Sheets below:

Typical Applications

HYREZ-RT can be used in food processing plants, cold rooms, canning factories, bottling plants, high foot traffic areas and environments where food safety, wet areas and heavy industrial use are all prerequisites.

Advantages

  • Economical
  • High early strength
  • High abrasion resistance
  • High chemical resistance
  • High impact resistance
  • High density
  • Nonhazardous (food safe)
  • Seamless
  • Non slip application
  • Low maintenance

Watch Points

  • While polyurethane screeds are chemically resistant, they can still stain and a sealer coat is recommended in areas where concentrated dyes, or foods or chemicals with staining history are exposed to the screeds for long periods of time.
  • A formal hygienic cleaning procedure is required to keep the surfaces hygienically clean and food safe.
  • Polyurethane screeds are not UV stable and will yellow under bright lighting and sunlight.

HACCP Compliance

For HACCP environments, HYREZ-RT comes with HACCP conformance certification issued by HAS Micro Labs, verifying ongoing compliance with on-site swab testing over the duration of the floor guarantee. Certification is quoted as an additional service by HAS Micro Labs. Please ask your sales representative for more information.

Directions for Use

Application Conditions: Application temperature should be between 15C and 25C. Employ the use of localized cooling or heating equipment if necessary. Try avoid applying over hot surfaces or previously heated areas. Substrates must have a moisture content of 12% maximum and tensile strength of 1.5 N/mm2 minimum.  

Surface Preparation: Surfaces need to be cleaned and flattened or imperfects will show through flow applied applications. Light grinding to remove all surface defects is recommended. Scabbling and acid etching is not recommended. If the substrate is porous or there is expected to be pin hole issues or moisture concerns, a scraper coat of MULTI PU PRIMER is recommended as a primer. Anchor grooves are to be cut at twice the thickness of the floor finish to a maximum of 10mm. Anchor grooves are to be cut around the floor perimeter, parallel to expansion joints, around upright structures, around drains, parallel to door thresholds, and at regular 3 meter spacing across the floor surface.  

Priming: MULTI PU RT SCREED is resin rich and will not require a primer on surfaces that are already sound and of suitable specification. If moisture is a concern, prime with MULTI PU PRIMER at 500 µm thickness using a trowel and allow to cure for 12 hours. If no blistering or pin holing occurs, continue with the final screed topping.

Application: Shake well the resin component to resuspend all the pigments in the liquid. In a pot mixer, premix the resin and the hardener until mixed together. While mixing, add in the powder aggregate gradually until all wetted out and lump free. Then transfer the mix onto the primed surface and level to the required thickness using a steel trowel or rake. Once level, use a spike roller to remove stubborn trowel lines and reaerate the screed. 

Do not spike roll beyond initial set (3-5 minutes of application) or the screed will not self-level and roll marks will remain in the screed. Ensure that anchor grooves are filled completely. Allow the screed to cure for 12 hours. Protect the curing floor from damp, condensation and direct water for at least 24 hours.

Sealing: Due to the 7-day full cure duration required, a sealer may need to be applied to protect the surface from premature exposure to staining materials such as grease, oils, rubber and oxidizing agents. One coat of MULTI MICRON SEALER can be applied over the surface of the floor before opening to foot traffic.

Limitations: Do not apply in humidity is expected to be greater than 90% RH, or if the surface temperature is less than 3C above the dew point. Ensure that the curing temperature never drops below 5C, and do not apply over concrete that is less than 25 MPa compressive strength. Colour variations can occur between batches so apply sections from the same batch of resin. Touching up will always be visible and should be avoided. If necessary, overcoat the entire surface with MULTI PU LC coating or MULTI PU SEALER in a similar colour.

Equipment Care

All tools should be cleaned with thinners or xylene immediately after use.

Packing

Supplied in 3.0LT RESIN, 2.2LT HARDENER and 25KG AGGREGATE.

REVISION: R4.1

HYREZ-RT

Data sheet

YIELD
15L
PACK SIZE
25kg